GM-10N | battery-operated thermal mass flow meter for gases |
GR-02 | thermal mass flow meter for gases with intelligent communication |
GS-01N | counter for compressed air, argon, nitrogen or CO2 |
GM-50 | air velocity transmitter to plug or screw in pipes or ducts |
GM-60 | differential pressure gas flow meter (not longer available) |
Please click on the highlighted row to display the related datasheet.
Profimess GmbH · Schleusenstr. 3 · D-27568 Bremerhaven ·
Deutschland
Tel.: +49 (0)471 9824 151 · Email: info@profimess.de
Media: dry, none-hazardous gases
Wetted: aluminum or stainless steel
max. Pressure: 0.2...11 bar abs.
max. Temperature: 50°C
Process connection: thread
Nominal widths: 1/4" up to 1/2"
Display: touchscreen 128 x 64 px
Output: up to 3 switches, adjustable
Measuring values: flow and totalizer
Supply: AA battery or 24 VDC
Media: dry, none-hazardous gases
Wetted: aluminum, stainless steel, Viton or EPDM, sensor from plastic
max. Pressure: 0.2...11 bar abs.
max. Temperature: 50°C
Process connection: thread
Nominal widths: 1/4" up to 1/2"
Output: (0)4...20 mA, 0...10 VDC, 1...5 VDC, 0...5 VDC or 2...10 VDC, RS485
Communication: Modbus or Profibus
Supply: 18...30 VDC
Media: compressed air, argon, N2 or CO2
Wetted: stainless steel and sensor
max. Pressure: 16 bar
max. Temperature: 60°C
Process connection: thread
Nominal widths: 1/4" up to 2"
Display: LED, 4 digits
Output: 1 analog output and 1 transistor switch
Switching load: 30 VDC, 250 mA
Supply: 18...30 VDC
Media: dry, compatible gases
Wetted: stainless steel and sensor
max. Pressure: 6,89 bar
max. Temperature: 100°C
Process connection: screwed in pipes or ducts directly or with compression fitting
Insertion length: 152.4 mmm up to 914 mm
Display: optional LED, 4.5 digits
Output: 4...20 mA, 3- or 4-wire
Supply: 12...35 VDC or 10...16 VAC
Media: gases, none-explosive, none-corrosive
Wetted: stainless steel
max. Pressure: 10 bar abs.
max. Temperature: 250°C
Process connection: welding nozzle with cutting ring joint
Nominal widths: from DN20
Output: 4...20 mA and 0...10 VDC for mass flow, pressure and temperature
Supply: 18...36 VDC, 3-wire